Solar Mounting Structure Bill of Materials: EPC Guide

Two structure quotes for the same array can differ by a wide margin and still describe different things. One includes rail splices and earthing lugs; the other prices them nowhere.…

Two structure quotes for the same array can differ by a wide margin and still describe different things. One includes rail splices and earthing lugs; the other prices them nowhere. A solar mounting structure bill of materials fixes that by listing every physical line the supplier must price, so the totals mean the same thing.

Axe Struct (Pty) Ltd manufactures and wholesale-supplies solar PV mounting structures for carport, ground-mount, rooftop and floating applications. This guide therefore builds the PV structure BOM around those four mounting types, with a row template for each.

What a solar mounting structure bill of materials covers

A structure-only BOM runs from the point where the module attaches down to the foundation. It lists the clamps, rails, beams, posts or columns, connection hardware, fasteners and foundation items in between. Modules, inverters, meters and cabling stay outside it unless the supplier’s scope says otherwise.

Whole-system lists mix those items in with the racking, which makes the structure cost hard to isolate. Keeping the structure list separate lets a procurement team compare mounting suppliers without panel and electrical pricing in the way.

Kit and package quotes need extra care. A kit may cover only part of the structure list, for example rails and clamps without the foundation or the connection hardware, so check its inclusions against the BOM rows before comparing any price. For carports, what a carport kit typically includes is a useful reference for that check.

A BOM does not replace structural design. It records the result of that design, and it is only as good as the layout and load basis behind it.

Mounting structure component list: posts, rails and clamps

Every mounting structure component list should give each group its own row, whatever the mounting type. The core groups are posts or columns, beams and rails, module clamps, connection hardware, fasteners and foundations. Each row carries a specification, a unit of measure and a count basis.

Structure component breakdown: posts, beams and rails

Each member gets its own row, so it can be checked directly against the layout drawing. A usable row records five things:

RowProfile typeMaterial and finishLength or cut basisCount basis
Posts or columnsStated section and sizeSteel, hot-dip galvanised, or aluminiumLength per piece, including embedmentPer row or bay
BeamsStated section and sizeAs aboveCut length per spanPer bay
RailsStated profileAluminium (anodised) or galvanised steelStock length or cut to rowPer module row

Material choice changes the profile, the finish and the coating basis on every one of these rows. The comparison of aluminium versus steel for solar mounting covers that trade-off.

A supplier who quotes “structure: 1 lot” has given the buyer nothing to check.

Clamps, brackets and connection hardware

Mid clamps and end clamps are separate rows, because the quantities differ and each is sized to the module frame height. Roof attachments, rail splices, base plates and earthing or bonding lugs each get their own line as well. If earthing sits in the electrical scope, record that on the row instead of leaving it blank.

A single “mounting hardware” figure cannot be compared line by line. A typical case: a quote shows one “roof mounting kit” line. Split it, and it turns out one supplier includes hooks, rails and splices while the other prices ballast trays and leaves the splices out. The rows make that visible in minutes.

PV structure BOM by mounting type: rooftop, ground, carport and floating

The rows differ by mounting type, so each type needs its own list. Readers still choosing between systems can start with this overview of solar mounting system types before building one.

Each table below uses the same columns: specification, unit of measure, count basis and quote reference. The quote reference is the supplier’s own line number, entered against the matching row, so two quotes can sit side by side.

Rooftop and ground-mount lines

Rooftop adds roof attachments: penetrating hooks, standing-seam clamps or ballast trays. The attachment rows should follow the rooftop bracket specifications for the roof type.

Rooftop lineSpecificationUnitCount basisQuote ref.
Roof attachmentsHook, standing-seam clamp or ballast trayEachPer support positionR1
RailsProfile, material, finishm or eachPer module rowR2
Rail splicesMatched to rail profileEachPer rail jointR3
Mid and end clampsFrame height, finishEachPer module interface and row endR4
Bonding lugsOr “electrical scope”EachPer rail or rowR5

Ground mount replaces roof attachments with piles or footings, and adds posts or purlins and bracing.

Ground-mount lineSpecificationUnitCount basisQuote ref.
Piles or footingsType, section, embedmentEachPer post positionG1
PostsSection, material, finishEachPer frameG2
Purlins or railsProfile, material, finishm or eachPer module rowG3
BracingSection, connection typeEachPer frame or bayG4
Clamps and fastenersSee fastener rowsEachPer module and jointG5

Carport and floating lines

Carports carry the heaviest members: columns, base plates, anchor bolts, and primary and secondary beams. Member sizes depend on span and load, which the guide to carport frame steel specifications and load requirements explains.

Carport lineSpecificationUnitCount basisQuote ref.
ColumnsSection, finishEachPer bay lineC1
Base platesThickness, plate sizeEachPer columnC2
Anchor boltsDiameter, length, gradeEachPer base plateC3
Primary beamsSection, finishEachPer bayC4
Secondary beamsSection, finishEachPer module rowC5

Floating systems swap the civil items for floats, mooring and anchoring lines, walkways and corrosion-compatible hardware.

Floating lineSpecificationUnitCount basisQuote ref.
FloatsType, role in arrayEachPer module or rowF1
Mooring and anchoring linesMaterial, lengthEach or mPer anchor pointF2
AnchorsType, holding basisEachPer mooring lineF3
WalkwaysWidth, materialm or eachPer access routeF4
HardwareMaterial compatible with water exposureEachPer connectionF5

Solar racking bill of quantities: counting from the array layout

Counts come from the array layout, never from a supplier’s rule of thumb. Module count and size, orientation, number of rows and the span between supports set the rails, clamps, posts and attachment points.

Write the counting rule beside each quantity, so a buyer can re-run it. A solar racking bill of quantities with rules attached looks like this:

  • Supports per rail: rail length divided by support span, rounded up, plus one.
  • Mid clamps per row: modules in the row minus one, multiplied by the number of rails.
  • End clamps per row: two for each rail.
  • Posts or attachments: supports per rail multiplied by rails per row, per frame layout.

A typical case: a row of 20 modules on two rails needs 38 mid clamps and 4 end clamps per row. If a quote shows a different figure, the buyer can see whether the layout or the rule differs.

Allowances for cut loss, breakage and spares

Quotes often differ on allowances, and a comparison is only valid when the quantities match. State cut loss, breakage and spares as a separate row or column, never folded into the base count. Then one supplier’s quantity of 1,000 and another’s of 1,050 can be traced to the same layout plus a stated allowance, not to a different design.

Fastener specifications and corrosion protection

Two quotes can show the same fastener count and still differ on grade and coating. Each fastener row should state material, coating, diameter, length, grade, washer type and tightening basis. The tightening basis is a torque value or a stated tightening method.

Coating and grade follow the site. An inland site, a coastal site, an industrial site and a floating array each expose steel and aluminium to a different corrosion load, so the same bolt specification will not suit all four. The finish stated on the member rows, such as hot-dip galvanised or anodised, should be consistent with the fastener coating beside it.

Dissimilar metals and site environment

The fastener metal has to suit the materials it joins. Where aluminium meets steel, state where isolation washers or sleeves separate them, and list those items as their own rows. Where a floating array puts hardware near water, the hardware material is part of the specification and not a detail to settle on site.

A fastener row that says only “M10 bolt” fails this test.

Foundations and civil scope

List piles or ground screws, concrete footings, ballast blocks and anchor blocks as separate priced rows. Write the basis beside each one: the ground data, the embedment or anchoring assumption, or the roof load limit a ballasted system must respect.

A ground-mount row priced per pile, with no embedment depth or ground assumption, cannot be checked against site conditions. The same applies to ballast: a price per block means little until the roof load limit and the block count are on the same line. Buyers should also confirm whether excavation, concrete supply and installation sit in the structure scope or in the civil scope, since those items often fall between the two.

Solar EPC procurement BOM: comparing supplier quotes line by line

Two quotes compare fairly only when they price the same rows, on the same design basis, units and quantities. An EPC procurement BOM works as the common template: every supplier prices against it, and anything priced outside it is flagged.

Normalising quotes to one line-item basis

Set the design basis first and send it with the BOM: module size and layout, wind load, any snow load, and the structural design code that applies on site. Without it, suppliers size members differently and the prices stop being comparable.

Then convert units. Some lines are priced per piece, some per metre and some per kilogram. Rails quoted per metre and posts quoted per kilogram must be converted to a single basis, normally the total per row, before any total is compared.

Exclusions, lead time and questions for each supplier

Record these for every supplier, next to the quote:

  • Exclusions, including any BOM row not priced.
  • Coating and material certificate scope: which members carry certificates and which do not.
  • Packaging and how the goods are delivered.
  • Lead time for the full order.

The BOM quantities set the order size, and the order size drives delivery. For planning, see the notes on manufacturer lead times in South Africa. The manufacturer quote guide for mounting structures explains how a request is processed.

EPCs, installers and wholesalers across South Africa and other African markets can request a quote from Axe Struct and ask for it to be priced against the BOM rows in this guide. The quote can then be returned line by line, with each row’s specification, unit and count basis stated.

Frequently asked questions

Does a solar mounting structure BOM include panels, inverters and cabling?

No. A structure-only BOM runs from the module attachment down to the foundation. Modules, inverters, meters and cabling are outside it unless the supplier’s scope states otherwise, so check the scope line before comparing totals.

What rows should a PV structure BOM contain at minimum?

Posts or columns, beams and rails, mid and end clamps, connection hardware, fasteners and foundations. Each row needs a specification, a unit of measure and a count basis. Mounting-type rows are added on top: roof attachments, piles or footings, base plates, or floats and anchoring.

How do I check that a supplier’s quantities are correct?

Re-run them from the array layout using the counting rule written beside each quantity. Module count and size, orientation, rows and support span drive the rail, clamp, post and attachment counts. Any gap between two quotes should trace to a stated allowance for cut loss, breakage or spares.

Why can two quotes with the same fastener count still differ in price?

Grade, coating, length and washer type change the cost of each fastener. A coating suited to an inland site is not the same as one specified for a coastal, industrial or floating site. Compare the full fastener specification row, not just the count.

Can a kit price be compared directly with a line-by-line quote?

Only after the kit’s inclusions are matched to the BOM rows. A kit can omit foundations, splices, earthing lugs or connection hardware. Add or flag the missing rows, then compare on the same basis.